Permit: T05CM04957


Addresses:

7782 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Permit Number - T05CM04957

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
11/22/2005 SHEET ROCK NAILING Approved IVRS - Inspection :*FIRE SEPARATION INSTALLATION FINISHED AT NORTH DEMISING WALL
11/16/2005 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*NEED TO PROVIDE U.L RATED SYSTEM FOR FIRE CAULKING
NEED ACCESS TO JOISTS & OTHER PENTRATIONS FOR FURTHER INSPECTION
11/14/2005 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection :*ALL PENETRATIONS NEED TO BE FIRE CAULKED & NEED TO PROVIDE FIRE CAULKING SYSTEM
11/14/2005 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1) CALL FOR ANOTHER INSPECTION AFTER FIRE CAULKING ALL PENETRATIONS
11/08/2005 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*OK TO ADD NEXT ( 2) LAYERS
CALL AFTER ??? CAULK & BEFORE TAPING
11/02/2005 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection :*PATCH EXISITING SHEET ROCK
RECAL WHEN 1ST LAYER PATCHED
JOG OUT WALL ABOVE BATHROOM AS DISCUSSED
PROVIDE FIRESTOP SYSTEM FOR PENETRATIONS
10/17/2005 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection :* CODE REVIEWS CHECK LIST IS FAULTY. ALLOWABLE AREA FOR VB BUILDING WITH GROUP A2 OCCUPANCY STARTS @ 6000 SQ FL WITH 75 % AREA INCREASE FOR FRONTAGE. YOU DO NOT SEEM TO MEET REQUIREMENTS FOR NON SEPARATED USE.
I APEARS THAT A 2 HR AREA SEPARATION WALL IS REQUIRED BETWEEN THIS SPACE AND CHINESE RESTAURANT NEXT DOOR.