Permit: T05CM04907

Parcel: 118121450


Addresses:

1300 S 2ND AV #01

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/13/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
02/10/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
THE CORRECTIONS FROM THE PREVIOUS INSPECTION HAVE NOT BEEN MADE - GALV NIPPS CANNOT BE USED WHEN COPPER ADAPTORS ARE USED FOR HOSE BIBS.
ALSO PIPING IN WALL MUST BE SECURED
02/06/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES FROM INTERMEDIATE INSPECTION OF 12/1/05
1. INTERMEMBERING OF DISSIMILAR MATERIALS IS PROHIBITED PROVIDE NON FERROUS PIPING AT HOSE BIBS ALSO
2. SECURE DROP TAPED FILL IN WALL AT UNSECURED HB LOCATION ON SOUTHEAST WALL.
3.USE APPROVED PIPE SUPPORTS TO SECURE DW DRAIN HOSE
4. PROVIDE PROTECTION OF EXPOSED ABS VENTS
5. COMPLETE TRIM ON TUB OVERFLOW