Permit: T05CM04885

Parcel: 13815026F


Addresses:

240 E TETON RD #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/03/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/26/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
OK TO COVER SEWER TO PROP. LINE
SUPPORT YARD WATER LINE
SUPPORT HORIZONTAL PIPING AT ALL CHANGES OF DIRECTION
USE LISTED PIPE CLAMPS TO SECURE PIPING
DO NOT STRAIN FITTINGS
TRAP AND TRAP ARM SHALL BE THE SAME SIZE
WATER TEST TUBS TO FLOOD LEVEL
01/24/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*PROVIDE CORRECT SIZE FOR LAVATORY TRAP ARM
OFFSET VENTS HORIZONTAL AT A MINIMUM 6" ABOVE FLOOD RIM OF FIXTURE
SUPPORT HORIZONTAL ABS AT CHANGE OF DIRECTION AND AT EVERY 4" THEREAFTER. USE LISTED PIPE SUPPORTS. A TEST ON TUB WASTE & OVERFLOW REQUIRED.