Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM04867
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/03/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER TED |
|
02/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR BLOCKING PANELS DO NOT REACH ROOF 2) 3 POINT BEARING TRUSSES DO NOT BEAR AT MID POINT 3) WRONG HOLDOWNS AT GARAGE/HOUSE SHEARWALL 4) 8/SD3 NOT AT 48" ON CENTER 5) STRAP NON OVERLAPING DBL TOP PLATES 6) C02BV MISSING RAT RUNS 7) GABLE END BRACES, SHEAR PANEL AND TRUSSES NOT NAILED TO ROOF SHEATHING |