Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM04796
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/22/2006 | FRAMING | Approved | IVRS - Inspection :* | |
02/16/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) GARAGE HEADER TRIMMERS TO SHORT AND EXTERIOR CLIP NOT APPROVED 2) NO DWV WATER TEST 3) FIRE STOP REQUIRES 2 LAYERS OF OSB 1/2" 4) INTERIOR NON BEARING WALLS MUST HAVE 1/2" CLEARANCE TO SCISSOR TRUSS 5) INTERIOR WALLS NOT ANCHORED 6) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 7) SHIM HEADERS 8) READ HEAD ANCHOR BOLTS LOOSE 9) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR J. RIVA 10) STOPPED INSPECTION-TOO MANY ITEMS |