Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM04795
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
12/20/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1 AND 2 FROM INSPECTION DATED 12/16/05 NOT COMPLIED WITH |
|
12/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRUSS R1 X A MISSING BRACE 2) TRUSS R1XD MISSING 2 BRACES 3) TRUSS R1X MISSING 2 BRACES 4) TRUSS H1 MISSING 1 BRACE 5) TRUSS H1D MISSING 1 BRACE 6) TRUSS HM1 MISSING 1 BRACE 7) STRUCTURE AT 17/D-1 NOT PER PLAN PROVIDE CITY APPROVED ENGINEER DETAIL FOR PRESENT CONSTRUCTION 8) ROOF SHEATHING NOT NAILED TO 5 TRUSSES |