Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM04789
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/30/2006 | FRAMING | Approved | IVRS - Inspection :* | |
01/27/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) REPAIR AT TJI CALLS FOR 8D'S NOT STAPLES AND HAVE STAMPED BY CITY OF TUCSON 2) FIREBLOCKS MISSING AT MASTER CLOSET AND TUB AREA DROPS 3) MISSING CLIPS AND HANGERS AT STRINGERS |
|
01/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH UPSTAIRS FRONT WINDOW NOT LATH AND SEAL ALL PENETRATIONS 2) PROVIDE ENGINEER REPAIR FOR TJI IN DEN 3) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR 4) METAL BOXES NOT GROUNDED 5) STRAP DBL TOP PLATE WEST WALL, DEN 6) CLIPS NAILED TO BOTTOM CORD OF TJI NOT ALLOWED AT 3 PT BEARING MUST USE WEB STIFFNERS 7) STOPPED INSPECTION |
|
01/25/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE STOP IN GARAGE AT BEAM 2) COMPLETE FURR OUT IN CLOSET FOR PLUMBING 3) REPLACE FIRE BLOCK AT PLUMBING 4) REPLACE BLOCKS BETWEEN TJI JOISTS 5) SUPPORT BOTH SIDES OF 4 GANG BOX AT ENTRY 6) FIRE STOP 2ND FLOOR PENETRATIONS 7) SOLID BLOCKS AT CANT. JOISTS 8) FIRE BLOCKS AT PLUMBING IN KITCHEN-2 X AND BELOW HOOD VENT 9) COMPLETE LATH AND SEAL ALL PENETRATIONS 10) STOPPED INSPECTION |
|
01/23/2006 | FRAMING | Cancelled | CANCELLED PER SUPERINTENDENT TRAVIS #240-8413 |