Permit: T05CM04767

Parcel: 140260560

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM04767

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/25/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
02/07/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ALL PIPING OK TO COVER, EXCEPT THAT FINAL APPROVAL IS PENDING PLAN REVISION FOR THE USE OF AIR ADMITTANCE VALUE AT KITCHEN SINK LOCATION. LETTER RECEIVED FROM DR. HORTON DESIGNER D. CUCCI AUTHORIZING USE OF AAV
02/06/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO TEST ON DWV
PROVIDE TEST ON DWV
USE OF AIR ADMITTANCE VALVE FOR KIT SINK WILL REQUIRE A PLAN REVISION. PLEASE RED LINE PLAN TO REFLECT PIPING SYSTEM INSTALLATION
02/03/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLAN SHOWS KIT SINK VTR INSTALL PER PLAN OR REVISE.
HORIZONTAL VENTING BELOW FLOOD RIM IS ALLOWED IF DRAINAGE FITTINGS ARE USED.
DRAINATE FITTINGS REQUIRED ON HORIZONTAL TO HORIZONTAL CHANGE OF DIRECTION
PROVIDE TEST ON TUB OVERFLOW