Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2008 | PLUMBING - FINAL | Approved | UNIT 50 OK | |
| 01/18/2008 | PLUMBING - FINAL | Cancelled | ||
| 01/17/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 50 KS CO NEEDS ADAPTOR FITTING W/PLUG DW HOSE CLAMP HB VAC BREAKER ON BACK SIDE |
|
| 10/25/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #52 APPROVAL ONLY |
|
| 10/23/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* DAP WATER CLOSET |
|
| 10/19/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT 47 APPROVED ONLY |
|
| 09/17/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #46 APPROVED UNIT #48 APPROVED UNIT #57 APPROVED |
|
| 09/13/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 57 -- CORRECTLY INSTALL KIT SINK & CO PLUG 48 -- KS CLIPS - INSTALL AND TIGHTEN ALL CLIPS FOR SINK. PROVIDE INSTALLATION INSTRUCTIONS FOR KS 46 -- KS CLIPS - INSTALL AND TIGTHEN ALL CLIPS FOR SINK PROVIDE INSTALLATION INSTRUCTIONS FOR KS PROPERLY INSTALL CO FITTING AT KS. VAC B LOCK SCREWS. |
|
| 08/22/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* #51 APPROVED |
|
| 08/15/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 49 AND 60 APPROVED |
|
| 08/14/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* #55 APPROVED UNIT #60 - PLUG AND COVER FD OR PROVIDE TRAP SEAL PROTECTION CAP UNUSED WASHER WASTE IN BACKYARD UTILITY SHED HAVE NOT SEEN PLANS FOR THIS MODEL |
|
| 08/13/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 49 - MISSING POP UP & CHINA BOWL CAPS. WATER NOT ON AT KS 45 - FINAL APPROVED 60 - TUB TRIM, TEMP CAP UNDER KS OR INSTALL DW |
|
| 08/02/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT 53 FINAL OK |
|
| 07/31/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #44 OK |
|
| 07/26/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* UNIT 53 NO CHANGE ON CROSS CONNECTION AT R O SYSTEM SINCE LAST INSP. POTABLE WATER CONNECTION TO SEWER SYSTEM IS A SERIOUS HEALTH CODE VIOLATION CONTINUED NOT READY INSP MAY RESULT IN REINSPECTION FEES |
|
| 07/24/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/20/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #54 APPROVED |
|
| 07/09/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* #54 -- HB VAC BREAKER. HB VAC BREAKERS CAN HAVE NO VALVES ON STRM. #44 -- MAKE CO WATER & GAS TIGHT W/THREAD SEALANT LAV POPE UP. SOV HANDLE ON WATER SERVICE VALVE DW NOT SECURE #53 -- RO SYSTEM REQUIRES AIR GAP. WC BOLT LOOSE CHINA BOWL CAP #58 -- FINAL OK |
|
| 07/03/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* AVOID TRAPPING DW HOSE AFTER HIGH POINT, FOOD WILL SETTLE AND SMELL. PROVIDE 3RD PARTY LISTING FOR TEKA SINK ANSI 304 FIXTURES SHALL HAVE UPC OR CSA APPROVAL |
|
| 06/27/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/29/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNITS 56 & 59 FINAL OK PROVIDE LARGER ACCESS OPENING AT SOV INSTALL HB VAC BREAKERS FRONT & BACK AT #57 |
|
| 05/24/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/22/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* ALL FIXTURES SHALL HAVE BEEN TESTED & LISTED TO CONFORM TO APPLICABLE STANDARDS. |
|
| 05/18/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 57 MISSING HB VAC BREAKER, PLEASE INSTALL ASAP UNIT 59 SECURE DW HOSE W/PIPE SUPPORT NOT WIRE TIE AVOID TRAPPING HOSE BETWEEN HIGH POINT AND BOSS FAUCET DOES NOT SEAL AT CONNECTION TO SINK, CORRECT AND PROVIDE LISTINGS FOR SINK AND FAUCET SHOWER HEAD CONNECTION LEAKS, SINK CONN TO COUNTER LEAKING IN BACK. |
|
| 05/15/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE CLEANOUT AT SINK 2. PROVIDE TWO HOLE CLAMP FOR DISHWASHER HOSE 3. PROVIDE APPROVED SUPPLIES FOR SINK & DISHWASHER 4. UNIT #59 |
|
| 09/29/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #44 SECURE DE TAPE CLEANOUT PLUG INSTALL HANDLE ON HW AND CW SHUT OFF VALVE OK TO OCCUPY AFTER COMPLETING. |