Permit: T05CM04760

Parcel: 11006159B


Addresses:

2861 N COLUMBUS BL

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/10/2008 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
09/27/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*.
1) OK #50 SUBJECT TO BLDG INSPECTOR
2) VERIFY DRILLING OF TRUSSES
08/22/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
SPLIT BOLT LISTED FOR A RUN & A TAP CONDUCTOR

OK ROUGH #52
07/26/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK 46 & 47 ROUGH
07/24/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
#47 & 47
1. PROTECT FEEDERS AT TOP PLATE
2. STAPLE NM CABLE 8" TO SINGLE GANG 12" OTHERS
07/19/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
07/17/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK ROUGH 48 & 57
06/29/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK LAUNDRY ROOM #50 & #51
UNITS 53, 52, 51 & 50 OK TO CLOSE UP SERVICES

1. NEED CITY STAMP FOR PLANS OF SERVICE
2. CLEARANCES SUBJECT TO L.HANLY
06/26/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK ROUGH #60
06/22/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PLEASE PROVIDE A DRAWING TO VERIFY SERVICE LOADS AND CONDUCTOR SIZES.
2. INSTALL SERVICE ENTRANCE CONDUCTORS AS PER MANUFACTURES INSTRUCTIONS
3. NOTE WATER BOND POINT TO BE ACCESSIBLE
4. FINISH PREVIOUS ITEMS #2,3,8
06/18/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
PLEASE RESCHEDULE SO ELECTRICIAN CAN ACCESS SERVICE

#60
1. LAUNDRY ROOM: CEILING BOX IS OVERFILLED
2. SECURE CABLES TO BOXES 312.5
ALSO, BRING FLUSH - ALSO, PLASTIC BOXES
3. PROPERLY GROUND BOXES
4. SECURE CABLES ABOVE PANEL
5. TIGHTEN LOOSE FITTINGS
6. CORRECTLY IDENTIFY GROUNDED CONDUCTORS
7. USE PROPER TOOLS TO CRIP COPPER SPLICES
8. USE APPROVED SCREWS TO MOUNT BOXES
05/03/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. HAVE BUILDING INSPECTOR CHECK FOR FIREWALL SEPARATION.
2. FINISH LAUNDRY ROOM

OK ROUGH 51 EXCEPT AS NOTED.
04/26/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OK WALLS UNIT 55 & 56
2. COMPLETE ITEM #6 FROM INSPECTION ON 4/19/07
FOR UNITS 55 & 56
04/24/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
STOP DRYWALL
FINISH PREVIOUS INSPECTION ITEMS
04/19/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. SUPPORT NM CABLES AS PER CODE
2. WE HAVE BOXES OVERFILLED
3. GROUND METAL BOXES
4. SECURE CABLES TO BOXES IN MULTI-GANG BOXES
5. SUPPORT CABLES ABOVE PANEL
6. SEPARATE GROUNDS & NEUTRAL AT SUB-PANEL
7. WHERE ARE PLANS FOR NEW LAYOUT
8. TIGHTEN LOOSE FITTINGS
9. WIRE SHEATH TO EXTEND 1/4" INTO BOXES
03/28/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
#59
1. TIGHTEN NM CONNECTORS AT PANEL
2. SEPARATE GROUNDS & NEUTRALS AT SUB-PANEL

OK WALLS
OK LAUNDRY ROOM #58
07/28/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK 601 ROUGH