Permit: T05CM04758

Parcel: 11006159B


Addresses:

2821 N COLUMBUS BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/17/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
17 - APPROVED
16 - APPROVED
01/10/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
#16 LAVATORY P-TRAP NOT PROPERLY INSTALLED
#11 APPROVED
HB VAC BREAKER LOCK SCREWS - VARIOUS LOCATIONS
10/31/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNIT #26 APPROVED (ONLY)
10/30/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
10/10/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNITS #13 AND 15 APPROVED
09/27/2007 PLUMBING - FINAL Cancelled
09/26/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
- TOILET RM WALL SECURE TUB SPOUT
- WB CORRECT SLOPE, CAP WATER LINES, INSTALL CO ON OPEN DRAIN PIPE
09/24/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- UNIT 13 SECURE HB, BREAK OFF LOCKING SCREW ON VAC BREAKER.
- USE PIPE CLAMP ON DW HOSE
- NOTE: WATER IS VERY HOT I RECOMMEND TEMPERING WATER TO NOT MORE THAN 12O DEG.
08/22/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNITS #18 AND 19 FINAL APPROVED
- UNIT 11 OK SECURE PEX AT LAVITORY
- UNIT 13 PROVIDE ACCESS FOR SLIP NUT TUB WASTE OR INSTALL

SOLVENT WELD WASTE & OVERFLOW
USE 1/2" TO SUPPLY NO MORE THAN TWO FIXTURES
SECURE PEX REMOVE METAL STRAPPING
ISOLATE FROM METAL
08/13/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT #18
- HOT & COLD WATER CROSSED AT KS
- ADJUST WATER HEATER TEMPERATURE TO A MAXIMUM
OF 120 DEG.
- PAINT EXPOSED ABS VENTS

UNIT #19
- NO HOT WATER AT KS
- ONLY ONE SLIP NUT ALLOWED DOWN STREAM OF P-TRAP
08/11/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) FINAL ONLY UNIT #21
08/02/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNITS #10 AND #12 FINAL OK
UNIT #23 FINAL OK
08/01/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
#24 FINAL INSP. ONLY OK
07/30/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNIT #25 FINAL INSP OK
07/26/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
HB ON EAST WALL MISSING VAC BREAKER
07/24/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNIT 14 -- FINAL INSP. ONLY OK
UNIT 25 -- ONLY ONE SLIP NUT ALLOWED DN STRM OF P-TRAP
MAKE CONNECTION TO EXISTING DWV RIDGID
07/20/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNIT #22 FINAL PLUMBING ONLY OK
UNIT #10 CAULK KS
UNIT #14 CHINA BOWL CAPS
UNIT #23 KS CO AND DW HOSE
UNIT #24 HB LEAKING & NO VAC. BREAKER KS CO DW HOSE CRACKED LAVITORY
UNIT #25 APPROVED BACKFLOW DEVICE REQUIRED FOR IRR SUPPLY
THREAD SEALANT ON CO, CAULK WC
LAVATORY - CANNOT OFFSET TRAP ARM W/SLIP NUTS
MAY OFFSET TAILPIECE OR USE APPROVED DRAINAGE FITTINGS.

THESE ARE FINAL PLUMBING INSPECTIONS; INTERMEDIATE INSPECTIONS WERE NOT PERFORMED.
07/19/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
UNIT #22 OK
07/17/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT 22 -- HB LEAKS AT HANDLE
SECURE DW HOSE, SINK DRAIN & SUPPLIES
INSTALL CO AT K.S
07/13/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
#20 OK
#24 HB VAC BREAKER ACCESS
07/11/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
KENT 784-1406