Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/17/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 17 - APPROVED 16 - APPROVED |
|
| 01/10/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* #16 LAVATORY P-TRAP NOT PROPERLY INSTALLED #11 APPROVED HB VAC BREAKER LOCK SCREWS - VARIOUS LOCATIONS |
|
| 10/31/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #26 APPROVED (ONLY) |
|
| 10/30/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 10/10/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNITS #13 AND 15 APPROVED |
|
| 09/27/2007 | PLUMBING - FINAL | Cancelled | ||
| 09/26/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* - TOILET RM WALL SECURE TUB SPOUT - WB CORRECT SLOPE, CAP WATER LINES, INSTALL CO ON OPEN DRAIN PIPE |
|
| 09/24/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - UNIT 13 SECURE HB, BREAK OFF LOCKING SCREW ON VAC BREAKER. - USE PIPE CLAMP ON DW HOSE - NOTE: WATER IS VERY HOT I RECOMMEND TEMPERING WATER TO NOT MORE THAN 12O DEG. |
|
| 08/22/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNITS #18 AND 19 FINAL APPROVED - UNIT 11 OK SECURE PEX AT LAVITORY - UNIT 13 PROVIDE ACCESS FOR SLIP NUT TUB WASTE OR INSTALL SOLVENT WELD WASTE & OVERFLOW USE 1/2" TO SUPPLY NO MORE THAN TWO FIXTURES SECURE PEX REMOVE METAL STRAPPING ISOLATE FROM METAL |
|
| 08/13/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT #18 - HOT & COLD WATER CROSSED AT KS - ADJUST WATER HEATER TEMPERATURE TO A MAXIMUM OF 120 DEG. - PAINT EXPOSED ABS VENTS UNIT #19 - NO HOT WATER AT KS - ONLY ONE SLIP NUT ALLOWED DOWN STREAM OF P-TRAP |
|
| 08/11/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) FINAL ONLY UNIT #21 |
|
| 08/02/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNITS #10 AND #12 FINAL OK UNIT #23 FINAL OK |
|
| 08/01/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* #24 FINAL INSP. ONLY OK |
|
| 07/30/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #25 FINAL INSP OK |
|
| 07/26/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* HB ON EAST WALL MISSING VAC BREAKER |
|
| 07/24/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT 14 -- FINAL INSP. ONLY OK UNIT 25 -- ONLY ONE SLIP NUT ALLOWED DN STRM OF P-TRAP MAKE CONNECTION TO EXISTING DWV RIDGID |
|
| 07/20/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #22 FINAL PLUMBING ONLY OK UNIT #10 CAULK KS UNIT #14 CHINA BOWL CAPS UNIT #23 KS CO AND DW HOSE UNIT #24 HB LEAKING & NO VAC. BREAKER KS CO DW HOSE CRACKED LAVITORY UNIT #25 APPROVED BACKFLOW DEVICE REQUIRED FOR IRR SUPPLY THREAD SEALANT ON CO, CAULK WC LAVATORY - CANNOT OFFSET TRAP ARM W/SLIP NUTS MAY OFFSET TAILPIECE OR USE APPROVED DRAINAGE FITTINGS. THESE ARE FINAL PLUMBING INSPECTIONS; INTERMEDIATE INSPECTIONS WERE NOT PERFORMED. |
|
| 07/19/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #22 OK |
|
| 07/17/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 22 -- HB LEAKS AT HANDLE SECURE DW HOSE, SINK DRAIN & SUPPLIES INSTALL CO AT K.S |
|
| 07/13/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* #20 OK #24 HB VAC BREAKER ACCESS |
|
| 07/11/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* KENT 784-1406 |