Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/17/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 10/08/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER UNIT #26 |
|
| 10/05/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/28/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 26 AND 17 OK WRAP PIPES W/FOAM AT MECH. RM WALL |
|
| 09/27/2007 | PLUMBING - INTERMEDIATE | Cancelled | ||
| 09/26/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 09/24/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/31/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 13 OK |
|
| 08/29/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/29/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 12X12 ACCESS REQUIRED FOR SLIP NUT WASTE |
|
| 08/27/2007 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - RI canceled | |
| 08/22/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNITS #18 AND 19 FINAL APPROVED - UNIT 11 OK SECURE PEX AT LAVITORY - UNIT 13 PROVIDE ACCESS FOR SLIP NUT TUB WASTE OR INSTALL SOLVENT WELD WASTE & OVERFLOW USE 1/2" TO SUPPLY NO MORE THAN TWO FIXTURES SECURE PEX REMOVE METAL STRAPPING ISOLATE FROM METAL |
|
| 07/05/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 15 OK |
|
| 07/03/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 16 OK INSIDE AT WASHER CONNECT UPSTAIRS UNITS TO 3/4 WATER SUPPLY |
|
| 06/15/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE SHOWER HEAD AND CONTROL VALVE 2) ? PLASTIC THREAD ADAPTOR CANNOT BE LOCATED IN A CONCEALED LOCATION |
|
| 06/06/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 11 TRAP ARM CANNOT EXCEED 1/4" PER FOOT SLOPE SECURE PIPING SECURE SHOWER HEAD & DIVERTER VALVE TEMPORARILY CAP OPEN DRAIN PIPING. RAG NOT ACCEPTABLE |
|
| 05/09/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNITS 18 & 19 HAVE NEW TUB VALVES INSTALLED OK TO COVER |
|
| 11/21/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 18 & 19 OK TO COVER TUB VALVES ARE EXISTING |
|
| 07/27/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SEE NOTES FROM ACTIVITY ...4757 |