Permit: T05CM04758

Parcel: 11006159B


Addresses:

2821 N COLUMBUS BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/17/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
10/08/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER UNIT #26
10/05/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
09/28/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
26 AND 17 OK
WRAP PIPES W/FOAM AT MECH. RM WALL
09/27/2007 PLUMBING - INTERMEDIATE Cancelled
09/26/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/24/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/31/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNIT 13 OK
08/29/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/29/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
12X12 ACCESS REQUIRED FOR SLIP NUT WASTE
08/27/2007 PLUMBING - INTERMEDIATE Cancelled IVRS - RI canceled
08/22/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #18 AND 19 FINAL APPROVED
- UNIT 11 OK SECURE PEX AT LAVITORY
- UNIT 13 PROVIDE ACCESS FOR SLIP NUT TUB WASTE OR INSTALL

SOLVENT WELD WASTE & OVERFLOW
USE 1/2" TO SUPPLY NO MORE THAN TWO FIXTURES
SECURE PEX REMOVE METAL STRAPPING
ISOLATE FROM METAL
07/05/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNIT 15 OK
07/03/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNIT 16 OK INSIDE AT WASHER CONNECT UPSTAIRS
UNITS TO 3/4 WATER SUPPLY
06/15/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE SHOWER HEAD AND CONTROL VALVE
2) ? PLASTIC THREAD ADAPTOR CANNOT BE LOCATED IN A CONCEALED LOCATION
06/06/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT 11
TRAP ARM CANNOT EXCEED 1/4" PER FOOT SLOPE
SECURE PIPING
SECURE SHOWER HEAD & DIVERTER VALVE
TEMPORARILY CAP OPEN DRAIN PIPING. RAG NOT ACCEPTABLE
05/09/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS 18 & 19 HAVE NEW TUB VALVES INSTALLED
OK TO COVER
11/21/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNIT 18 & 19 OK TO COVER
TUB VALVES ARE EXISTING
07/27/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
SEE NOTES FROM ACTIVITY ...4757