Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNITS 8 & 9 APPROVED NEED TO INSPECT NEW WORK IN OLD OFFICE ON EAST END ABS VENT REQUIRES LATEX PAINT ALSO, NEED CERTIFICATION OF EXISTING IRRIGATION PVB EXTERIOR CLEAN OUTS REQUIRE TEF TAPE |
|
| 08/09/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #7 FINAL INSP. ONLY OK |
|
| 08/02/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #6 FINAL ONLY OK |
|
| 08/01/2007 | PLUMBING - FINAL | Cancelled | ||
| 07/31/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #3 FINAL INSP. ONLY OK |
|
| 07/30/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* - UNITS #1 AND #4 FINAL INSP. ONLY OK - USE THREAD SEALANT ON ALL THREADED SEWER & DRAIN CONNECTIONS. - HB VAC BREAKER MISSING ON HB BETWEEN #2 & 3 |
|
| 07/26/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT #1 PROVIDE 12" ACCESS FOR TUB WASTE |
|
| 07/24/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT #1 ACCESS HOLE REQUIRED FOR EXISTING SLIP NUT TUB WASTE HAS REVEALED EXCESSIVE SLOPE ON KS TRAP ARM AND A CHANGE IN SIZE OF TRAP ARM. TRAP ARM SLOPE MUST BE MAINTAINED AT 1/4" PER FOOT TO PREVENT SIPHONING OF TRAP. TRAP AND TRAP ARM REQUIRED TO BE OF THE SAME SIZE. |
|
| 07/23/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/21/2007 | PLUMBING - FINAL | Not ready for Inspection | SPECIAL INSP. #1201 PAID W/CHECK UNIT #4 KIT SINK MISSING CO PIPING NOT SECURED TOILET NOT SEALED UNIT #7 DW HOSE NOT SECURED CO PLUG NOT SEALED UNAPPROVED BACKFLOW PROTECTION ON IRRIGATION |
|
| 07/20/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT #5 FINAL INSP. OK UNIT #2 FINAL INSP. OK UNIT #1 BACKFLOW ASSEMBLY, CHINA BOWL CAPS, DW HOSE UNIT #3 DW HOSE UNIT #6 DW HOSE THESE ARE FINAL INSPECTIONS ONLY THERE HAVE BEEN NO INTERMEDIATE APPROVALS |
|
| 07/19/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* #5 KS CO AND SECURE PIPING VAC B LOCK SCREW |