Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ALL AREAS ON UNITS #8 & #9 |
|
| 10/05/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/07/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 07/27/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* - DO NOT CONCEAL ANY MORE PIPING PRIOR TO INSPECTION. - PLUMBING PIPES, FITTINGS AND FIXTURES THAT ARE IN ORIGINAL CONDITION ARE NOT REQUIRED TO MEET CURRENT CODES BUT ALL MODIFICATIONS WILL BE REQUIRED TO MEET CURRENT CODES. - KIT SINKS REQUIRE CLEAN OUTS, ALSO LAUNDRY PIPING THAT HAS BEEN REPLACED W/ABS REQUIRE CLEAN OUTS. - USE CORRECT TRANSITION FITTINGS AT TRANSITION TO ABS - INSTALL CORRECT RADIUS DRAINAGE FITTINGS. - INSTALL SAFETY PLATES ON PIPING WITHIN 1 1/4" OF WALL - TRAP ADAPTERS REQUIRED. - BACKFLOW PROTECTION REQUIRED ON IRRIGATION PIPING AND ALL HOSE BIBBS. - AAV'S CANNOT HAVE A VALVE ON STREAM - TUBS SHALL BE WATER TESTED. - FILL TUBS W/WATER. RUN TEST OK. - SECURE DW HOSES AS HIGH AS POSSIBLE UNDER SINK. |