Permit: T05CM04757

Parcel: 11006159B


Addresses:

2801 N COLUMBUS BL

Inspection Status: Partial Approval

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/08/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL AREAS ON UNITS #8 & #9
10/05/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/07/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
07/27/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
- DO NOT CONCEAL ANY MORE PIPING PRIOR TO INSPECTION.
- PLUMBING PIPES, FITTINGS AND FIXTURES THAT ARE IN ORIGINAL CONDITION ARE NOT REQUIRED TO MEET CURRENT CODES BUT ALL MODIFICATIONS WILL BE REQUIRED TO MEET CURRENT CODES.
- KIT SINKS REQUIRE CLEAN OUTS, ALSO LAUNDRY PIPING THAT HAS BEEN REPLACED W/ABS REQUIRE CLEAN OUTS.
- USE CORRECT TRANSITION FITTINGS AT TRANSITION TO ABS
- INSTALL CORRECT RADIUS DRAINAGE FITTINGS.
- INSTALL SAFETY PLATES ON PIPING WITHIN 1 1/4" OF WALL
- TRAP ADAPTERS REQUIRED.
- BACKFLOW PROTECTION REQUIRED ON IRRIGATION PIPING AND ALL HOSE BIBBS.
- AAV'S CANNOT HAVE A VALVE ON STREAM
- TUBS SHALL BE WATER TESTED.
- FILL TUBS W/WATER. RUN TEST OK.
- SECURE DW HOSES AS HIGH AS POSSIBLE UNDER SINK.