Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK 8 & 9 S.T.O.I 1. FINISH WORK TO OFFICE -- NEED ALL INSPECTION |
|
| 12/18/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MISSING SMOKE DETECTORS 2. MISSING EXHAUST FANS |
|
| 11/29/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
| 08/30/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK TO COVER WALLS BEHIND SERVICES ELECTRIC & FIRE BLOCKING |
|
| 08/28/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) RECEIVED CHECK #1250 FOR $108.00 |
|
| 08/08/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK #3 |
|
| 08/07/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* NO ONE HOME #3 |
|
| 08/02/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK #1 |
|
| 07/31/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* FINISH LABELING UNIT #1 |
|
| 07/26/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* NO WORK DONE |
|
| 07/24/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* VERIFYING PAPERWORK |
|
| 07/22/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* RECEIVED CK#1201 -- $432.00 #3 - A. BOXES MORE THAN 1/4" FROM BOX TO SURFACE - 314.20 B. BOND PANEL C. LABEL PANEL AS PER 408.4 D. IDENTIFY NEUTRAL CONDUCTOR E. PROTECT CONDUCTOR WITH A BUSHING F. OUTSIDE RECEPTACLE NOT GFCI PROTECTED G. GROUND SWITCHES H. CHECK MAKE UP IN JUNCTION BOXES I. ROOF: ID UNGROUNDED CONDUCTOR, STRAP SEALTITE, LOOSE FITTINGS #7: A. MISSING COUNTER RECEPTACLE B. BOXES MORE THAN 1/4" FROM BOX TO SURFACE 314.20 C. GROUND SWITCHES D. OUTSIDE RECEPTACLE NOT GFCI PROTECTED E. LABEL PANEL AS PER 408.4 F. BOND PANEL G. MISSING DEAD FRONT COVER H. PLEASE VERIFY SUB-PANEL AMPACITY ALL ROOF UNITS CHECK IDENTIFICATION OF UNGROUNDED CONDUCTORS, SUPPORT OF SEAL TITE, LOOSE FITTINGS & LABELING OF EMT'S |
|
| 07/19/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/18/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK UNITS 4 & 5 INSPECTED 6/30/06 UNIT #1: 1. INSTALL CONNECTOR AT HOOD AND WIRING COMPARTMENT COVER 2. ANTI-TIP FOR RANGE 3. CORRECTLY LABEL PANELS 408.4 -- NO ABBREVIATIONS. |
|
| 08/03/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK ELEC. FINAL #6 #2 |