Permit: T05CM04733

Parcel: 119280310


Addresses:

2700 S LA CHOLLA BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T05CM04733

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
03/30/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
03/28/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ROOF LINE @ 143/TOP WEST OF 133 AND CORRIDOR WALK
03/24/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
7'4" @ 143; 3RD LIFT 133 & CORRIDOR
03/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
7'4" 133 A & B; 4' EAST BLD (143)
03/21/2006 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
LAP SLICES FOR GRADE 60 STEEL IS 47" WHEN 2 BARS IN ONE CELL. REFERENCE 51.1
YOU MUST HOLD GROUT DOWN 8" FOR SINGLE BAR CELLS.