Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T05CM04733
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
03/28/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ROOF LINE @ 143/TOP WEST OF 133 AND CORRIDOR WALK |
|
03/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 7'4" @ 143; 3RD LIFT 133 & CORRIDOR |
|
03/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 7'4" 133 A & B; 4' EAST BLD (143) |
|
03/21/2006 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* LAP SLICES FOR GRADE 60 STEEL IS 47" WHEN 2 BARS IN ONE CELL. REFERENCE 51.1 YOU MUST HOLD GROUT DOWN 8" FOR SINGLE BAR CELLS. |