Permit: T05CM04698

Parcel: 106030150

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/10/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
PLUMBING FINAL OK

PLUMBER PLEASE NOTE: VENT FITTINGS INSTALLED BELOW THE FLOOD RIM ARE TO BE DRAINAGE TYPE (USE COMBO INSTEAD OF SANTEE - WHICH ISN'T APPROVED ON ITS BACK ANYWAY)
09/04/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- CO PLUGS REQUIRE THREAD SEALANT
- REMOVE LOCK SCREW ON VAC BREAKER
- PROVIDE PROOF OF INSP. OF WATER LINE OFFSET AT RP LOCATION
- MACHINE SCREW INTO FACTORY TAP REQUIRED
- GLUE F/P CLEANOUT ADAPTS ON SEWER
08/31/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. TIE UP DISHWASHER DRAIN HOSE WITHIN 2" OF DRAIN BOARD HEIGHT
2. EXPOSE ALL CLEANOUTS
3. "THIS BLDG. HAS NON-METALLIC INTERIOR WATER PIPING"
08/23/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
OK TO ASSEMBLE WASHER/DRYER UNITS CLEANOUTS OK
08/13/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*