Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/20/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1. CLOSET FLANGES TO BE INSPECTED UNDER 03075 2. MAY NOT INTERMINGLE ABS & PVC CAP OFF ALL OPEN PIPES IMMEDIATELY |
|
| 03/02/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 11-15 OK TO COVER WALLS AND CEILING RECALL FOR CLOSET FLANGE INSPECTION |
|
| 02/26/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* KAREN 272-2475 9 & 10 OK TO COVER #11 CONNECT LAUNDRY TO 3/4 BRANCH SECURE 1" OVERHEAD SAFETY STRAPS |
|
| 02/22/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 10 WH ON PLATFORM REQUIRES DRAIN PAN SECURE TUBING AT WASHER BOX UNIT 9 T&P NOT PIPED 4-8 OK TO COVER WRAP WASTE KIT BELOW TUB W/FOAM BEFORE FILLING IN WITH CONCRETE. CLOSET FLANGES NOT YET SECURED W/FASTENERS PIPE SHALL BE EVEN W/TOP OF FLANGE MAY BE INSPECTED LATER QUICK CLOSING VALVES REQUIRE HAMMER ARRESTORS FOR FINAL. |
|
| 02/21/2007 | PLUMBING - INTERMEDIATE | Cancelled | CANCELLED PER KAREN OF WARRIOR CONST. #272-2475 | |
| 02/15/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* KAREN 272-2475 LEAKS AT TUB OVERFLOW, TEST TO FLOOD LEVEL SECURE PEX AT 32" AND ISOLATE FROM METAL SUPPORT HORIZONTAL PVC AT EACH END AND NOT EXCEEDINGLY. |
|
| 02/07/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) UNITS 4-10 ONLY 2) REQUIRE 2 X PIPE DIAMETER AT WASHER TRAP 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4) PVC TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AT THE END OF BRANCHES-THEN NO MORE THAN FOUR BETWEEN HANGERS 5) REQUIRE 18" OF COPPER AT SERVICE, AND WATER HEATER |
|
| 03/02/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |