Permit: T05CM04618

Parcel: 116260180

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/08/2006 FRAMING Approved IVRS - Inspection :*
1) REINSPECT
03/07/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO MESSAGE RETRIEVED
2) NO ACCESS-GATES LOCKED
3) NO ANSWER AT DOOR-STOPPED INSPECTION
03/02/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED X BRACE AT SOUTH GABLE TRUSSES
2) BLOCK DUCT BOOTS 3 SIDES
3) FIRE BLOCK ALL FURRED WALLS
02/23/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT 2" ABS AT BOTTOM PLATE IN SHOWER
2) SUPPORT 1 1/2" ABS VENT 90 DEGREE ABOVE LAV
3) NAIL PROTECT PEX AT TOP PLATE IN TOILET ROOM
4) NAIL PROTECT FLEX CONDUIT
5) NO LIGHT IN TOILET ROOM
6) OUTLET CONFIGURATION, ON WEST WALL OF MASTER BED, DOES NOT MATCH PLAN OR MEET CODE
7) GAS PIPE IN WRONG PLACE FOR FIRE PLACE-RELOCATE AND RE-PRESSURE TEST
02/17/2006 FRAMING Not ready for Inspection IVRS - Inspection :*