Permit: T05CM04609

Parcel: 12205039F


Addresses:

4409 E SENECA ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM04609

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/27/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH PREVIOUS INSPECTION
02/23/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH NOTE 1 PREVIOUS INSPECTION
2) COMPLY WITH NOTE 3 PRVIOUS INSPECTION
3) ANCHOR BOLT MISSING GARAGE BRACED WALL
4) COMPLY WITH DETAILS 11/S4 AND 12/S4 CARPORT
02/14/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH DETAIL 13/S3 DBL KING STUDS AND ALL HARDWARE
2) COMPLY WITH DETAIL 5/S4 2 EACH A.35 EACH STUD STAGGERED
3) NAIL EVERY HOLE H2.5'S THROUGHOUT
4) COMPLY WITH DETAIL 16/S4 HARDWARE AND LAG BOLTS
5) PER DETAIL 11/S3 1/2" ANCHOR BOLTS REQUIRED 2 EACH 1' FROM EACH PANEL END
6) NAIL PARAPET OSB
7) PROVIDE 1/8" GAP OSB ROOF PANELS ALL EDGES AND ENDS