Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM04570

Parcel: 118272830

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM04570

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/09/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/06/2005 EXT METAL CLIPS/EXT SHEATHING Denied 1) NAIL PROTECT ELECTRIC FROM OUTSIDE
2) REPLACE DAMAGED STUDS THROUGHOUT HOUSE
3) HOLDOWNS LEFT REAR OF HOUSE NEED RETRO FIT
4) OVERSPAN SOUTH WALL
5) REPLACE ALL SHEAR PANELS SOUTH EAST CORNER AND EAST WALL