Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/05/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HAVE DETAIL SHOWING TRUSS HANGERS AS THD26 APPROVED BY PLAN CHECK
2) NEED SIMPSON HTT22 HD'S AT DINING ROOM-PAGE 2 OF DRAWINGS
3) NEED RECEPTACLES BOTH SIDES OF OFFICE ENTRY-WALLS OVER 2' LONG
4) DOOR BELL TRANSFORMER CANNOT BE LOCATED IN CLOSET
5) NEED RECEPTACLE SOUTH OF ENTRY IN GREAT ROOM
6) NAIL STOPS DRYER VENT AT BLOCKING
7) GAS PRESSURE LESS THAN 1 POUND
8) NEED ACCESS PANEL FOR MASTER TUB
9) NEED ADDITIONAL FRAMING FOR SHEETROCK LIDS BOTH FURNACE ROOMS
10) STUCCO MESH MUST BE INSTALLED PRIOR TO APPROVAL OF INTERMEDIATES
03/21/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) AT FRAME INSPECTION NEED H.D.'S AT DINING ROOM
2) NEED TRUSS CALC'S
3) NEED SIZES OF LU HANGERS. NOT SPECIFIED ON FRAMING DETAILS
4) PROCEED AT OWN RISK UNTIL TRUESSES VERIFIED WITH CALC'S
03/20/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1. ADD A35s PER DETAIL 6.6 AT LEDGERS
2. 6 16d EACH STUD PER DETAIL 6.6
3. CHECK TRUSSES FOR PLUMB & WITHIN TOLERANCES
4. NO TRUSS CALCS ON SITE TO DETERMINE WHAT SIZE LU HANGERS REQUIRED.
5. ADD INTERIOR H/D AT DINING ROOM
6. EXTERIOR SIDING NAILING AND CLIPS OKAY
7. OK TO WRAP AND DRY IN