Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM04536

Parcel: 136140980

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM04536

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/06/2006 FRAMING Approved IVRS - Inspection :*
03/03/2006 FRAMING Partial Approval IVRS - Inspection :*
1) ADD SUPPORT UNDER STAIR LANDING
2) ADD BLOCKS UNDER GLU LAM FRONT DOOR
3) ADD BLOCKING UNDER WEST GIRDER TRUSSS BETWEEN FLOORS
4) SUPPLY MASTER BATH EXTENDS INTO ROOM
5) OK TO INSULATE