Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* FLANGES OK |
|
| 05/03/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES ARE REQUIRED TO BE SECURED TO FLOOR WITH CORROSION RESISTANT FASTENERS. 3" FLANGES ARE NOT CORRECTED. INSTALL HB VAC BREAKERS. OK TO COVER YARD WATER. |
|
| 04/26/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* GAS PIPING IN PONY WALL BOTH UNITS OK BLUE TRACER WIRE ATTACHED TO NON-METALLIC PIPING IS REQUIRED. YARD WATER BETWEEN SERVICE FOR #1 AND #2 ONLY. CONNECTIONS AT HOUSE SERVICE OK INSTALL HB VACUUM BREAKERS YARD WATER FROM THE METER TO SERVICE OF UNIT #1 HAS NOT BEEN INSPECTED. CONNECTION TO METER HAS NOT BEEN INSPECTED. CORRECTION ON CLOSET FLANGES OF UNIT #1 HAVE NOT BEEN MADE. CLOSET FLANGES INSTALLED IN UNIT 2 ARE 3" HB FLANGES GLUED INSIDE A 4" PIPE. THIS IS NOT AN ACCEPTABLE USE OF FITTINGS. INSTALL 4" FLANGES IN UNIT #2. FLANGES REQUIRED TO BE SECURED. |
|
| 02/27/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ALL AREAS EXCEPT CLOSET FLANGES. DUTCHMAN REQUIRED. SEE SEC. 316.3.2 "CLOSET BENDS MUST PRESENT A SMOOTH SURFACE EVEN WITH TOP OF CLOSET FLANGE." RECALL FOR CLOSET FLANGE INSPECTION BEFORE SETTING TOILETS. |
|
| 02/24/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ALL AREAS EXCEPT AT KIT. SINKS, WASHER BOXES AND OVERHEAD HORIZONTAL ABS ABOVE BATHROOM PROVIDE SWEEP FOR HORIZONTAL CHANGE OF DIRECTION, SUPPORT/SECURE PEX AT WASHER BOX LOCATION. INSTALL PIPE SUPPORT ON HORIZONTAL ABS AT CHANGES OR DIRECTION. PROVIDE WATER TEST ON SHOWER PANS CLOSET FLANGES NEED TO BE INSPECTED GAS PRESSURE TEST OK PROVIDE REVISED PLAN FOR ADDITION OF GAS DRYER INSTALL SAFETY PLATE AT DROP IN WALL AT SERVICE LOCATION. CALL FOR GAS PRESSURE TEST INSPECTION 03050 AFTER COMPLETING. OK TO COVER PIPING PROVIDE THAT THE CORRECTIONS ARE MADE. |