Permit: T05CM04526

Parcel: 14023117B

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/08/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
FLANGES OK
05/03/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGES ARE REQUIRED TO BE SECURED TO FLOOR
WITH CORROSION RESISTANT FASTENERS.
3" FLANGES ARE NOT CORRECTED.
INSTALL HB VAC BREAKERS.
OK TO COVER YARD WATER.
04/26/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
GAS PIPING IN PONY WALL BOTH UNITS OK
BLUE TRACER WIRE ATTACHED TO NON-METALLIC PIPING IS REQUIRED.
YARD WATER BETWEEN SERVICE FOR #1 AND #2 ONLY.
CONNECTIONS AT HOUSE SERVICE OK
INSTALL HB VACUUM BREAKERS
YARD WATER FROM THE METER TO SERVICE OF UNIT #1 HAS NOT BEEN INSPECTED.
CONNECTION TO METER HAS NOT BEEN INSPECTED.
CORRECTION ON CLOSET FLANGES OF UNIT #1 HAVE NOT BEEN MADE.
CLOSET FLANGES INSTALLED IN UNIT 2 ARE 3" HB FLANGES GLUED INSIDE A 4" PIPE.
THIS IS NOT AN ACCEPTABLE USE OF FITTINGS.
INSTALL 4" FLANGES IN UNIT #2.
FLANGES REQUIRED TO BE SECURED.
02/27/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL AREAS EXCEPT CLOSET FLANGES.
DUTCHMAN REQUIRED. SEE SEC. 316.3.2 "CLOSET BENDS MUST PRESENT A SMOOTH SURFACE EVEN WITH TOP OF CLOSET FLANGE."
RECALL FOR CLOSET FLANGE INSPECTION BEFORE SETTING TOILETS.
02/24/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL AREAS EXCEPT AT KIT. SINKS, WASHER BOXES AND OVERHEAD HORIZONTAL ABS ABOVE BATHROOM
PROVIDE SWEEP FOR HORIZONTAL CHANGE OF DIRECTION, SUPPORT/SECURE PEX AT WASHER BOX LOCATION.
INSTALL PIPE SUPPORT ON HORIZONTAL ABS AT CHANGES OR DIRECTION.
PROVIDE WATER TEST ON SHOWER PANS
CLOSET FLANGES NEED TO BE INSPECTED
GAS PRESSURE TEST OK
PROVIDE REVISED PLAN FOR ADDITION OF GAS DRYER
INSTALL SAFETY PLATE AT DROP IN WALL AT SERVICE LOCATION.
CALL FOR GAS PRESSURE TEST INSPECTION 03050 AFTER COMPLETING. OK TO COVER PIPING PROVIDE THAT THE CORRECTIONS ARE MADE.