Permit: T05CM04526

Parcel: 14023117B

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
04/26/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
02/27/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
02/24/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) INSTALL NAIL PLATES WHERE ROMEX IS LESS THAN 1 1/4" BACK FROM SURFACE OF STUDS
2) SUPPORT ROMEX WITHIN 12" EACH TERMINATION, AND AT 4 1/2" INTERVALS, THIS INCLUDES ACCESSIBLE ATTICS PER NEC
3) OUTSIDE LIGHT BOXES NEED CLAMP TYPE ROMEX CONNECTORS-NO GROMMETS