Permit: T05CM04500

Parcel: 126062400


Addresses:

834 N IRVING CI

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
05/30/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
05/19/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/03/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REFEE ON ELECTRICAL
2) MAKE UP ALL WIRES IN BOXES
3) SECURE ALL ROMEX 8" FROM BOXES
4) GROUJD ALL METAL BOXES
5) ? SCREWS NEEDED CEILING FAN BOXES
6) CONCEALED JUNCTION BOX IN ATTIC SPACE
7) ATTIC OUTLET GABLE END NOT ON PLAN
8) MISSING GFCI OUTLET SOUTH EXTERIOR WALL
9) WIRE NOT MADE UP TO ALL OUTLET BOXES
10) ROMEX MUST TERMINATE INTO ALL CAN LIGHTING BOXES
11) MASTER CLOSET SWITCH WRONG SIDE OF WALL
12) SWITCH IN MASTER BEDROOM NOT ON PLANS
13) OUTLET MISSING CIRCUIT 19 PLAYROOM SOUTH WALL
14) NAIL PROTECT THROUGHOUT
15) CIRCUIT 14 A/C CIRCUIT NOT RUN
05/02/2006 ELECTRIC - INTERMEDIATE Cancelled CANCELLED BY KIM GREEN 326-9038
05/02/2006 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) CANCELLED
04/26/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAKE UP ALL WIRES IN BOXES
2) SECURE ELECTRIC WIRES 12" FROM SERVICE PANEL ENTRANCE AT REAR
3) SECURE WIRES 12" FROM BOXES
4) FINISH ELECTRICAL WIRING
5) GROUND METAL BOXES
6) PANCAKE BOXES USED ARE NOT APPROVED FOR FANS