Permit: T05CM04495

Parcel: 140378250

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/02/2006 FRAMING Approved IVRS - Inspection :*
01/30/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1. FIRESTOP SECOND FLOOR PENETRATIONS
2. ANCHOR BOLTS MISSING GARAGE SHEER WALL
3. HOLD DOWNS MISSING GARAGE SHEAR WALL
4. STAIRS EXCEED 3/8" RISE DIFFERENCE
5. SHEAR WALL SILL PLATE NOT NAILED PER PLAN
6. FIRE STOP MECH CHASE
7. FURNACE NOT INSTALLED PER INSTALLATION MANUAL
8. PROVIDE AN ORIGINAL FURNACE INSTALLATION MANUAL
9. MASTER BATH TOILET NOT PROPERLY VENTED
10. FIRE STOP FIRE PLATE CHASE
STOPPED INSP. NEXT FAILURE WILL REFEE
01/24/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL ALL PENETRATIONS THRU LATH
2) TIGHTEN ALL AB'S
3) FIRESTOP 2ND FLOOR PENETRATIONS THROUGHOUT
4) PROTECT COPPER TUBING AT TOP PLATE BY WATER HEATER
5) AB MISSING BEHIND FIREPLACE AND GARAGE SHEARWALL
6) CONMPLETE H.D.'S
7) FLOOR TRUSS CUT AT STAIRWAY
8) CLIP STUDS AT INTERIOR BEARING WALL BEHIND H. BATH SHOWER 2ND FLOOR
9) FIRESTOP CAHSE AT H. BATH 2ND FLOOR
10) FIREBLOCKS MISSING AT BED/GARAGE
11) NUMBER OF CLOSETS EXCEEDED FOR B-VENT
12) STOPPED INSPECTION-TO MANY ITEMS