Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM04478
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :*WATER TEST UNDERGROUND WASTE & VENT WITH LAV DRAIN TO 10' AFF.OK PIPE WRAPS OK. SUITE 133,139, 151 PLEASE KEEP ALL PERMIT CARDS ON SITE. |
|
10/06/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*PROVIDE WATER TEST ( BALL LET GO) EXPOSE CONNECTION TO EXISTING SEWER. |
|
09/20/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLEASE LOOK AT ISOMETRIC PLUMBING DRAWING. YOUR LAV DRAIN IS REQUIRED TO BE 1 1/2 PIPING MAXIMUM WITH A MAXIMUM LENGTH OF 30" YOUR ROUGH WILL NOT ACCOMIDATE THIS INSTALLATION. PLEASE HAVE A CONTACT PHONE NUMBER FOR YOUR PLUMBING CONTRACTOR AT NEXT INSPECTION. |