Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2005 | FRAMING | Approved | IVRS - Inspection :* 1) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR W. NORTH |
|
| 12/20/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/16/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NAIL LATH AT 6" ON CENTER AND SEAL PENETRATIONS 2) HOLDOWN NUTS LOOSE 3) MTT 28B HOLDOWN MISSING BEHIND HALL TUB 4) STUD MISSING AT KITCHEN ISLAND OVERSPAN 5) PROVIDE EXTERIOR CLIP APPROVAL 6) CRIPPLE STUDS ABOVE 8050 SHORT 7) MASTER BATH GFCI LOOSE 8) TERMINATE WIRES IN BOXES 9) NAIL PROTECT PLUMBING 10) STOPPED INSPECTION-TOO MANY ITEMS |