Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/15/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING STUCCO |
|
| 11/14/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 11/10/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 11/08/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL ALL LATHE PENETRATIONS 2) NAIL/STAPLE STUCCO MESH AT EAST GARAGE WALL 3) NO DWV TEST 4) MOVE COLD PEX MINIMUM 1 1/4" FROM BOTTOM OF TRUSS AT ENTRY 5) PROTECT CONDENSATE DRAIN 6) COMPLETE H.D.'S 7) COMPLETE HVAC DUCT ABOVE KITCHEN 8) PROTECT 220 CONDUCTOR OVER HALL WAY FROM TRUSS GANG PLATES |
|
| 11/07/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |