Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | CHECK HOLDOWNS AT INTER, | |
| 10/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALL STRUCTURAL PANELS MUST BE INSTALLED WITH LONG DIMENSION ACCROSS STUDS. NOTE 6 SHEAR SCHEDULE 2) HAVE ENGINEER OF RECORD EXCAVATE ALL SPAULED HOLDOWNS AND PROVIDE CITY OF TUCSON APPROVED REPAIR 3) MTT 28 B HOLDOWN MISSING ANCHOR BOLTS 4) NAIL 2 X 12 SHEAR TRANSFER TO DBL TOP PLATE AT 8" ON CENTER 5) PERMIT STATES B ELEVATION C INSTALLED 6) YOU MUST PROVIDE ACCESS TO ROOF |
|
| 10/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) NAIL MISSED ROWS ON ROOF 2) KERF TIGHT JOINTS ON ROOF 3) MORE NAILS NEEDED IN SHEAR X-FER |