Permit: T05CM04440

Parcel: 12810080A


Addresses:

200 S CRAYCROFT RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/09/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CLOSET FLANGES
04/06/2007 PLUMBING - INTERMEDIATE Partial Approval SHALL SEE CORRECT CLOSET FLANGES INSTALLATION FOR APPROVAL PRIOR TO SETTING STOOLS
03/06/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER DISTRIBUTION 2ND LEVEL IN WALL & OVERHEAD
100 PSI TEST OK

1. SHALL MAKE ACCOMODATION FOR CORRECT INSULATION INSTALLATION OVERHEAD ON HOT & HOT RETURN PIPING.
03/01/2007 PLUMBING - INTERMEDIATE Partial Approval WATER PIPING 1ST FLOOR AIR TEST WITH RISER TO 2ND FLOOR OK
02/13/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST. WASTE & VENT THRU ROOF OK