Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) H2.5 CLIPS MISSING AT BEARING WALL PER 7/DT2 2) EPC CAPS MISSING 4 X 6-6 X 6 AT GLB GARAGE 4 X 6 NOT UNDER GLU LAM BEAM 3) 4 X 4 POSTS MISSING AT STAIRS 4) TWO 4 X 6 POSTS MISSING UNDER 3 1/8 X 16.5 GLB 5) GARAGE SW6 NOT NAILED 4 X 12 6) LEDGERS MISSING H2.5 AND A.35 CLIPS PER 11/DT2 7) OK TO DRY IN |
|
| 04/14/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTERIOR CLIP AND ROOF COVERED WITHOUT INSPECTION 2) EXPOSE ALL FRAME AND ROOF SHEATHING |
|
| 10/25/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT COMPLETE ENOUGH TO INSPECT 2) NO PLANS/PERMIT ON SITE |