Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM04409
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/09/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :*DWV WATER TEST IS OK ALL CORRECTIONS HAVE BEEN MADE |
|
| 11/04/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*NO HUB COUPLING IS ONLY APPROVED ON NO HUB CAST IRON.USE SOLVENT ?? COUPLING FOR ABS SUPPORT ALL PIPING IN CORRECT MANNER |
|
| 10/27/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*EXPOSE WATER & SEWER CONNECTIONS UNDERGROUND. CANNOT LOCATE A C.O TEE IN A HORIZONTAL POSITION USE A TWO WAY C.O REMOVE FERNCO COUPLING AND REPLACE WITH APPROVED COUPLING A BLOCK( MASONRY) IS NOT AN APPROVED METHOD OF BLOCKING SEWER LINE. PROVIDE A WATER TEST ON BLDG SEWER PROVIDE A VACUUM BRAKER @ HOSE BIB INSULATE DOMESTIC WATER SUPPLY UP TO MODUAL |