Permit: T05CM04400


Addresses:

1315 S BURDOCK DR


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T05CM04400

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/07/2006 BUILDING - FINAL Approved IVRS - Inspection :*
08/02/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PENDING B-VENT
07/27/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE CONDENSATE DRAIN
2) COMPLETE STUCCO REPQIR AT CONDENSATE DRAIN
3) ATTIC ACCESS MUST BE SLEF CLOSING
4) COMPLETE GAS PIPING TO FURNACE AND CONNECT
5) CLEAN CONDENSATE DRAIN PAN
6) PROVIDE FURNACE INSTALLATION MANULA FOR PROPER VENTING REQUIREMENTS
7) PROVIDE 22" X 30" CATWALK FROM ATTIC ACCESS FURNACE WITHOUT OBSTRUCTION
8) REFEE WILL APPLY AT NEXT FAILURE
07/26/2006 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*