Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM04392

Parcel: 140378330


Addresses:

6798 S AQUILINE DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/01/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RIBBON NOT NAILED AT ENTRY
2) SOUTH 7/SD2 MISSING
3) 2ND FLOOR PLATE NOT BEARING 4 FEET WEST WALL
11/23/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP TOP PLATES AT 2 X 6/2 X4 INTERCHANGE ON NORTH WALL
2) REPLACE BLOCK IN 2 X 6 BALLOON FRAME ON NORTH WALL
3) NAIL OFF RIBBON