| 12/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/29/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RIBBON NOT NAILED AT ENTRY 2) SOUTH 7/SD2 MISSING 3) 2ND FLOOR PLATE NOT BEARING 4 FEET WEST WALL |
|
| 11/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP TOP PLATES AT 2 X 6/2 X4 INTERCHANGE ON NORTH WALL 2) REPLACE BLOCK IN 2 X 6 BALLOON FRAME ON NORTH WALL 3) NAIL OFF RIBBON |