Permit: T05CM04388

Parcel: 11205001A

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T05CM04388

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/18/2006 ELECTRIC - INTERMEDIATE Approved
04/10/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER SOFFITS.
04/07/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. FINISH RACEWAYS AND WIRE PULL.
2. BOXES ARE OVERFILLED.
3. PAY REINSPECTION FEE.
04/05/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. NEED TO PAY REINSPECTION FEE
2. FINISH WIRING
3. FRAME ATTIC ACCESS OPENINGS
04/04/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. COMPLETE WIRING CALL WHEN READY
03/08/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK RACEWAY COVER 2ND LIFT -- PIPES ARE WRAPPED
02/03/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK 1ST LIFT
02/02/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
EMT CONDUIT, ELBOWS AND FITTINGS NEED PROTECTION FROM CORROSION (WALLS TO BE FILLED) PER NEC 358.10(B) OTHERWISE USE PVC OR ANOTHER METHOD APPROVED FOR CONCRETE FILL.