Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/25/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) NEED TO INSTALL TRAPS ON DRAIN LINES |
|
| 06/21/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) KNOCKOUT MISSING SERVICE PANEL 2) ARC FAULT IN BEDROOM NOT WORKING PROPERLY 3) NEED TO VERIFY GROUND RODS 4) A/C UNIT NEES 3/4 VENTED TRAP ON CONDENSATION LINE-ATTACHED TO ? BLOCKS |
|
| 05/22/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS VISIBLE FROM STREET 2) PAINT ROOF VENTS ABS 3) BUBBLE COVER ALL GFCI OUTLETS EXTERIOR 4) VACUUM BREAKER HOSE BIBBS 5) SEAL KNOCKOUTS MAIN PANEL ? PLUMBING TYPE 6) EXTERIOR LIGHT MISSING LAUNDRY ROOM 7) VERIFY GROUND OR INSTALL GROUND RODS MAIN SERVICE 8) PROVIDE SAFE ACCESS TO ROOF 9) INSTALL REGISTERS 10) SEAL WATER CLOSET BASES 11) SMOKE DETECTORS REQUIRED DEDICATED CIRCUIT 12) HIGH/LOW COMBUSTION RELIEF VENTS NEEDED LAUNDRY ROOM 100 CU INCHES EACH 13) DRIP LEG WATER HEATER 14) ARC FAULT PROTECT REAR BEDROOM |
|
| 05/09/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE ITEMS 1 THRU 5 FROM PREVIOUS INSPECTION |
|
| 04/11/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BEDROOM OUTLETS MUST BE ARC FAULT PROTECTED 2) SMOKE DETECTORS MUST BE INTERCONNECTED 3) MECHANICAL NOT COMPLETE/NO THERMOSTAT 4) PROVIDE ACCESS TO ROOF 5) COMPLY WITH PREVIOUS INSPECTIONS 6) 200 AMP SERVICE NOT ON PLANS 7) SHOW PROOF OF APPROVALS 8) ROOF TOP UNIT NOT ON PLANS 9) MET ON SITE WITH OWNERS WHO UNDERSTAND ROOF TOP UNIT AND 200 AMP SERVICE PANEL MUST BE ADDED TO DRAWINGS |
|
| 04/10/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTERIOR STUCCO NOT COMPLETED 2) LABEL CIRCUITS MAIN SERVICE PANEL 3) BEDROOM OUTLETS MUST BE ARC FAULT PROTECTED 4) PROTECT 220 WAY TO ROOF TOP UNIT 5) PROVIDE ACCESS TO ROOF 6) VACUUM AT BREAKERS ON HOSE BIBS 7) NO LIGHT FIXTURE REAR DOOR 8) PAINT ROOF VENTS 9) PROVIDE ACCESS TO ROOF 10) EXTERIOR BOX NOT MADE UP FRONT ENTY 11) SECURE GAS LINE EXTERIOR 12) PROVIDE PROOF OF ALL APPROVED NECESSARY INSPECTIONS PRIOR TO FINALS 13) STOPPED INSPECTIONS EXTERIOR |