Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/04/2006 | FRAMING | Approved | IVRS - Inspection :* 1) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR J. RIVA |
|
| 01/03/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALL 3 CLIPS MUST BE ATTACHED TO TRUSS-NOT NAILER 2) NO PRESSURE TEST ON POTABLE WATER 3) KITCHEN SINK REQUIRES 1 1/2" VENT TO ROOF 4) HALL BATH REQUIRES 2" VENT TO ROOF 5) MASTER TOILET REQUIRES 2" VENT TO ROOF 6) MASTER TUB REQUIRES 2" VENT TO ROOF 7) BUILD TO PLAN OR REVISE PLAN TO AS BUILT 8) BEARING STUD CUT LIVING ROOM INTERIOR WALL AT DUCT 9) PROVIDE TRUSS DRAWINGS 10) ANCHOR INTERIOR BEARING WALL 11) SHIM HEADERS |