Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/13/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 01/11/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ALL ORIGINALS FOR SPECIAL INSPECTIONS |
|
| 01/10/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT 2) FAU ARE IN ATTIC NOT READY FOR INSPECTION |
|
| 01/09/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINAL GRADE NOT COMPLETE 2) BACK WATER VALVE MISSING AND CLEANOUT NOT TO GRADE 3) CONDENSATE LINE MISSING 90 DEGREE ELBOW 4) EXTERIOR GFCI NEXT TO CONDENSOR WON'T RESET AND DISCONNECT BOX NOT SECURED 5) PROVIDE LOCK OUT DEVICE FOR ELECTRIC WATER HEATER 6) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT 7) FAU PAN FULL OF CONSTRUCTION DEBRIS AND SPARK PLATE NOT INSTALLED |
|
| 01/06/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FUSES IN DISCONNECT |