Permit: T05CM04345

Parcel: 118272770

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM04345

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/26/2005 FRAMING Approved
10/25/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HANGER MISSING NAILS AT GARAGE J-TRUSSES
2) LOOK OUT CUT AT FIREPLACE AREA
3) BLOCK AT 8 FT MISSING GARAGE SHEAR
4) KITCHEN WALL STUDS CUT
5) ITEM 03050 NOT REQUIRED-NO GAS/ALL ELECTRIC
6) OK TO NET
10/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING 2-KING STUDS AT GARAGE GIRDER AND FRONT B/R
2) SHIM 3-POINT BEARING TRUSSES
3) STRAP DBL TOP PLATE NOT CABIN TIED AT GARAGE MANN DOOR
4) ADD STUD AT WEST WALL
5) 3" VTR MISSING AT HALL BATH
6) NAIL PROTECT ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD
7) ITEM 03050 NOT REQUIRED/NO GAS-ALL ELECTRIC