Permit: T05CM04341

Parcel: 11105291B

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T05CM04341

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/13/2006 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
04/10/2006 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
1. NO ACCESS. SPACE LOCKED! 3RD TIME
2. TWICE THE JOB WAS REJECTED, NOT PROPERLY FINISHED.
04/05/2006 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
THE BACKDRAFT DAMPERS IN THE EXHAUST FANS ACTUALLY HAVE TO WORK PROPERLY.
PROVIDE SPECS. ON CLOTHES DRYERS OR PROVIDE MAKE UP AIR.
STILL NO KITCHEN VENTS INSTALLED.
UNIT 2 DRYER VENT STILL HAS A SCREW IN IT, SUPPLY DUCT TO LIVING ROOM IS SMASHED, CEILING BOX IN BEDROOM NEEDS BACKING.
03/31/2006 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE 100 SQ.IN. MAKE UP AIR IN LAUNDRY ROOMS IT OVER 200 CFM
REPAIR OR PROVIDE BACKDRAFT DAMPERS IN EXHAUST FANS.
PROVIDE KITCHEN EXHAUST AS PER PLANS
CONDENSATE DRAIN HAS NOT SLOPE.
PROVIDE MIN 1/8" PER FT
REMOVE ANY SCREWS IN DRYER VENTS.
ALL CRIMPED ENDS MUST GO SAME DIRECTION AS AIR FLOW.
PROVIDE SCREEN IN EXHAUST T-TOPS
RECONNECT EXHAUST DUCT 2ND FLOOR TO WALL LOUVER
SECURE DRYER VENTS TO WALL LOEVERS
USE POP RIVETS OR TAPE
03/27/2006 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
THESE SHOULD BE UNLOCKED, ACCESSIBLE DURING BUSINESS HRS.
NO MESSAGE -- NO ACCESS!