Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T05CM04341
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/13/2006 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
04/10/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio 1. NO ACCESS. SPACE LOCKED! 3RD TIME 2. TWICE THE JOB WAS REJECTED, NOT PROPERLY FINISHED. |
|
04/05/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* THE BACKDRAFT DAMPERS IN THE EXHAUST FANS ACTUALLY HAVE TO WORK PROPERLY. PROVIDE SPECS. ON CLOTHES DRYERS OR PROVIDE MAKE UP AIR. STILL NO KITCHEN VENTS INSTALLED. UNIT 2 DRYER VENT STILL HAS A SCREW IN IT, SUPPLY DUCT TO LIVING ROOM IS SMASHED, CEILING BOX IN BEDROOM NEEDS BACKING. |
|
03/31/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE 100 SQ.IN. MAKE UP AIR IN LAUNDRY ROOMS IT OVER 200 CFM REPAIR OR PROVIDE BACKDRAFT DAMPERS IN EXHAUST FANS. PROVIDE KITCHEN EXHAUST AS PER PLANS CONDENSATE DRAIN HAS NOT SLOPE. PROVIDE MIN 1/8" PER FT REMOVE ANY SCREWS IN DRYER VENTS. ALL CRIMPED ENDS MUST GO SAME DIRECTION AS AIR FLOW. PROVIDE SCREEN IN EXHAUST T-TOPS RECONNECT EXHAUST DUCT 2ND FLOOR TO WALL LOUVER SECURE DRYER VENTS TO WALL LOEVERS USE POP RIVETS OR TAPE |
|
03/27/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* THESE SHOULD BE UNLOCKED, ACCESSIBLE DURING BUSINESS HRS. NO MESSAGE -- NO ACCESS! |