Permit: T05CM04341

Parcel: 11105291B

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM04341

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/29/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/28/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) 2" TRAP ARM AT KITCHEN SINKS REQUIRES 2" P-TRAP
2) WATER CLOSETS AND ALL PLUMBING FIXTURES TO BE MADE WATER TIGHT
3) IF PEX IS USED IN BLDG FOR WATER DISTRIBUTION SIGNAGE IN ELECTRICAL PANELS REQUIRES NON BONDED WATER PIPING
4) YARD WATER PIPING WAS NEVER INSPECTED, PROVIDE LISTING FOR MATERIAL TYPE USED, PVC OR COPPER IS ? ON APPROVED PLAN, MATERIAL TYPE USED HAS NO LISTING MARKINGS VISIBLE AND COULD REQUIRE DEEPER BURIAL DEPTH DEPENDING ON LISTING BECAUSE OF LOCATION IN DRIVE WAY
5) FUTURE TEE CONNECTION AT EAST HOSE BIB LOCATION COULD REQUIRE BACKFLOW PROTECTION IF USED AS LAND SCAPING WATER SOURCE
12/26/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
WHO LOOKED AT YARDWATER PIPING?
NOT ON PERMIT CARD - STILL REQUIRED
NO GAS TO BLDGS BUT IT IS ON THE CARD
COMPLETE ALL WORK BEFORE CALLING FINAL