Permit: T05CM04340

Parcel: 12204043A

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
12/13/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
12/11/2006 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLEASE PRODUCE APPROVED PLAN FOR WALL.
YOU NEED TO PROVIDE PROPER COVERAGE
FOR BOND BEAM STEEL.
07/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
#1101 WEST WALL TO 20'
07/05/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
#1101 WEST WALL TO 18'6"
06/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
UNIT #1101 WEST WALL TO 14'8"
06/27/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) UNIT #1101 E. WALL TO 17'-4"/20'
06/26/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/21/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
#1102 WEST WALL TO 17'4"
06/20/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
#1103 W. WALL TO 18'
06/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
#1103 E. WALL TO 18'2", #1101 E WALL TO 17'4"
05/31/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12'7"-17'4" -- #1104 EAST & WEST WALLS.
05/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL WALLS TO 12'7 OK TO GROUT
05/18/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NO ONE ON SITE.
05/12/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL WALLS TO 9'4"
05/02/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL WALLS TO 8'8"
04/11/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES B.1/D.1, B2/D2
04/10/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NO PLANS AT SITE
04/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES B5 - D5
A4-B4
0-4'8"
01/24/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) NEED TO HAVE SPECIAL INSPECTION PER SPECIAL CONDITIONS ON PERMIT
01/23/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) WHERE PLAN KEY NOTE "Q" DESIGNATED, THE VERTICAL REINFORCEMENT MUST BE (2) #5 REBARS. (4) #4 REBAR DOES NOT NECESSARLY EQUAL (2) #5 REBARS
2) THE LAP SPLICES FOR #5 REBAR IS 32". THIS MEASUREMENT IS FROM TOP OF STEM WALL TO TOP OF VERTICAL REBAR
3) HORIZONTAL REINFORCEMENT AT STEM WALL MUST BE CONTINOUS THROUGH CONTROL JOINTS, MAY NOT BE LAPPED WITHIN 8' ? A CONTROL JOINT AND NEED TO BE WRAPPED (DUCT TAPE IS ACCEPTABLE) REFERENCE DETAIL 14 ON SHEET S1.1
4) CALL FOR REINSPECTION UNDER THE ITEM 01010 (STEM WALL/RETAINING WALL)