Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/06/2006 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/01/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BARE BULB LIGHT FIXTURES ARE NOT ALLOWED IN CLOTHES CLOSETS MUST HAVE GLOBE OVER BULB. 2. AT LEAST BATTERY OPERATED SMOKE DETECTORS -- ARE REQUIRED IN EACH BEDROOM AND ROOM/HALL LEADING TO BEDROOM. 3. WATER HEATER VENT MUST BE 1" FROM COMBUSTIBLE MATERIAL AND EXTEND 5 FEET ABOVE TOP OF WATER HEATER WITH AN APPROVED WEATHER CAP. 4. INSTALL COVERS ON ALL ELECTRIC BOXES. 5. NO GAS PRESSURE TEST. |