Permit: T05CM04318

Parcel: 11806087B


Addresses:

2245 W SAN JUAN TR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM04318

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/05/2006 FRAMING Approved IVRS - Inspection :*
01/11/2006 FRAMING Partial Approval IVRS - Inspection :*
1) PROVIDE DETAIL FOR 4 X 6 CONNECTION AT CMU COLUMN
01/04/2006 FRAMING Partial Approval IVRS - Inspection :*
1) MAIN GARAGE OK
2) NEW ROOF ATTACHMENT 8' X 11' INCOMPLETE TO EXISTING
3) COMPLETE ALL ELECTRIC AND GROUND AT SUB-PANEL PER PLAN
4) UNDERGROUND CONDUIT FROM 200 AMP EXISTING TO NEW SUB-PANEL GARAGE OK TO COVER