Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM04318
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/05/2006 | FRAMING | Approved | IVRS - Inspection :* | |
01/11/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PROVIDE DETAIL FOR 4 X 6 CONNECTION AT CMU COLUMN |
|
01/04/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MAIN GARAGE OK 2) NEW ROOF ATTACHMENT 8' X 11' INCOMPLETE TO EXISTING 3) COMPLETE ALL ELECTRIC AND GROUND AT SUB-PANEL PER PLAN 4) UNDERGROUND CONDUIT FROM 200 AMP EXISTING TO NEW SUB-PANEL GARAGE OK TO COVER |