Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM04304
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/22/2005 | FRAMING | Approved | IVRS - Inspection :* | |
12/21/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING ELECTRIC AND PLUMBING 2) APPROVED TO INSULATE 3) SEE PREVIOUS |
|
12/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STAPLE WIRE 8" FROM BOX IN GARAGE 2) BLOCK AND NAIL CUT SHERWALL IN GARAGE 3) H2.5 MISSING ON GARAGE GIRDER 4) BANG PLATE FRONT BED, MASTER CLOSET CONDENSATE LINE 5) TOP PLATES SPLICED TO CLOSE TOGETHER MUST STRAP (LR) 6) NO DWV 7) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR C. TREVILLYAN |
|
12/19/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF PLATE SURFACES/WATER HEATER 2) NO DWV WATER TEST 3) RED HEAD ANCHOR BOLTS LOOSE 4) BHG-1 TRUSS NOT MID-POINT BEARING 5) INTERIOR BEARING WALLS NOT ANCHORED AT 6' ON CENTER PER PLAN AND IRC 6) NAIL PROTECT CONDENSATE 7) 4 BEARING STUDS OVER NOTCHED AT MASTER CLOSET/CONDENSATE 8) MASTER TOILET REQUIRES 15" TO FINISHED WALL 9) PLUMBING NOT COMPLETE 10) STOPPED INSPECTION-TOO MANY ITEMS |