Permit: T05CM04304

Parcel: 141092540


Addresses:

6603 E LADONNA LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM04304

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/22/2005 FRAMING Approved IVRS - Inspection :*
12/21/2005 FRAMING Partial Approval IVRS - Inspection :*
1) PENDING ELECTRIC AND PLUMBING
2) APPROVED TO INSULATE
3) SEE PREVIOUS
12/20/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STAPLE WIRE 8" FROM BOX IN GARAGE
2) BLOCK AND NAIL CUT SHERWALL IN GARAGE
3) H2.5 MISSING ON GARAGE GIRDER
4) BANG PLATE FRONT BED, MASTER CLOSET CONDENSATE LINE
5) TOP PLATES SPLICED TO CLOSE TOGETHER MUST STRAP (LR)
6) NO DWV
7) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR C. TREVILLYAN
12/19/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF PLATE SURFACES/WATER HEATER
2) NO DWV WATER TEST
3) RED HEAD ANCHOR BOLTS LOOSE
4) BHG-1 TRUSS NOT MID-POINT BEARING
5) INTERIOR BEARING WALLS NOT ANCHORED AT 6' ON CENTER PER PLAN AND IRC
6) NAIL PROTECT CONDENSATE
7) 4 BEARING STUDS OVER NOTCHED AT MASTER CLOSET/CONDENSATE
8) MASTER TOILET REQUIRES 15" TO FINISHED WALL
9) PLUMBING NOT COMPLETE
10) STOPPED INSPECTION-TOO MANY ITEMS