Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 03/27/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OK TO COVER OSB IN GARAGE 2) ALL ELSE NOT READY |
|
| 03/24/2006 | BUILDING - FINAL | Partial Approval | 1) OK TO COVER H.D. RETROS IN GARAGE 2) LEAVE OSB OPEN FOR NEXT INSPECTION AND LEAVE REPAIR DETAIL 3 LSI REPORT FOR NEXT INSPECTION |
|
| 03/20/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ELECTRIC CONVENIENCE OUTLET NOT ALLOWED UNDER BAR TOP GREATER THAN 6" OVERHANG. 2. M.BR SECURITY SYSTEM MUST BE ARC FAULT PROTECTED 3. UNDER MOUNT KITCHEN SINK MUST BE CAULKED 4. NO RANGE ANTI TILT 5. GARAGE HOLD DOWNS REQUIRE WET SET ANCHOR BOLTS RED HEADS INSTALLED PROVIDE ENGINEERS APPROVED REPAIR. 6. PROVIDE POST TENSION TAG AT WATER SHUT OFF VALVE |