Permit: T05CM04279

Parcel: 141092470


Addresses:

6563 E LADONNA LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM04279

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/23/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/19/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
South east gable truss not clipped per 1/sd3 report
#8 shearwalls not nailed at 4" on center ? ends and edges per plan-repeat
Bird boards not nailed per 1/SD-3
No ladder access to roof
To many repeat items
5 days to pay a reinspection fee
01/18/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1 SD3 NOT COMPLIED WITH NAIL AT 8" ON CENTER (REPEAT)
2) CLIP GABLE END TRUSS S.E. CORNER
3) SHEAR BLOCKING PANELS NOT NAILED THRU ROOF AT 6" ON CENTER PER 4/SD3 REPEAT
4) ROOF SHEATHING NOT NAILED AT 6 AND 12 OR STAPLED AT 4" AND 8" REPEAT
5) #8 SHEARWALLS NOT NAILED AT 4" ON CENTER ON EDGES-REPEAT
01/17/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE PREVIOUS
01/13/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING NAILING IN OSB SHEARWALLS, INCORRECT NAIL SPACING REAR SHEAR #8=4" B 12" ON CENTER
2) SHEAR BLOCKING PANELS (SPACING) CAN'T FIND ON PLANS
3) SOME PANELS NOT NAILED TO ROOF DECK
4) MISSING NAILS IN P.A.'S, ALL P.A.'S REQUIRE 16D COMMONS, NOT SINKERS
5) NO TRUSS DRAWINGS ON SITE
01/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KSD 248 STRAPS MISSING 2/SD3
2) 4 KING STUDS REQUIRED AT GARAGE ? 5 SD2
3) NO TRUSS DRAWINGS ON SITE
4) 1/SD3 NOT COMPLIED WITH
5) STOPPED INSPECTION