Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/26/2006 FRAMING Approved IVRS - Inspection :*
01/18/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) SEWER DRAIN REQUIRES 1/4"/FT PITCH
2) FIRE STOP FLOOR PENETRATIONS
3) PEX MUST BE 12" FROM CAN LIGHTS
4) ANCHOR BOLTS LOOSE AND MISSING THROUGHOUT
5) ELECTRIC OUTLETS NOT ALLOWED UNDER COUNTER TOP GREATER THAN 6"
6) FLAME SHIELD NOT INSTALLED
7) FAMILY ROOM OUTLETS CANNOT BE ON KITCHEN CIRCUIT
8) MAX ALLOWED STAIR BULL NOSWE 1 1/4"
9) MINIMUM STAIR RUN 10" FROM BULL NOSE TO BULL NOSE
10) FIRE STOP DUCT CHASE
11) 10/DT1 NOT DONE 2ND FLOOR
12) #6 SHEAR NOT NAILED PER PLAN
13) NAIL PROTECT WIRES
14) DUCTS NOT COMPLETE
15) STOPPED INSPECTION