Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/26/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/18/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) SEWER DRAIN REQUIRES 1/4"/FT PITCH 2) FIRE STOP FLOOR PENETRATIONS 3) PEX MUST BE 12" FROM CAN LIGHTS 4) ANCHOR BOLTS LOOSE AND MISSING THROUGHOUT 5) ELECTRIC OUTLETS NOT ALLOWED UNDER COUNTER TOP GREATER THAN 6" 6) FLAME SHIELD NOT INSTALLED 7) FAMILY ROOM OUTLETS CANNOT BE ON KITCHEN CIRCUIT 8) MAX ALLOWED STAIR BULL NOSWE 1 1/4" 9) MINIMUM STAIR RUN 10" FROM BULL NOSE TO BULL NOSE 10) FIRE STOP DUCT CHASE 11) 10/DT1 NOT DONE 2ND FLOOR 12) #6 SHEAR NOT NAILED PER PLAN 13) NAIL PROTECT WIRES 14) DUCTS NOT COMPLETE 15) STOPPED INSPECTION |